www.rkiinstruments.com35-3001A-01-02Combustible Gas Sample-Draw DetectorOperator’s ManualPart Number: 71-0328Revision: P2Released: 9/17/14
6 • 35-3001A-01-02 Combustible Gas Sample-Draw DetectorSpan PotThe span pot is located below the zero pot (see Figure 1). Use a small flat blade scre
35-3001A-01-02 Combustible Gas Sample-Draw Detector • 7InstallationThis section describes procedures to mount the sample-draw detector in the monito
8 • 35-3001A-01-02 Combustible Gas Sample-Draw Detector2. Close and latch the housing door.NOTE: The sample-draw detector is shipped with the mountin
35-3001A-01-02 Combustible Gas Sample-Draw Detector • 9ring, if it came out, in the orientation shown in Figure 4. 4. Screw the inlet fitting tube n
10 • 35-3001A-01-02 Combustible Gas Sample-Draw DetectorInstalling the Exhaust Line1. Loosen the nut on the exhaust fitting until 3 threads are visib
35-3001A-01-02 Combustible Gas Sample-Draw Detector • 118. Connect the wires to the applicable detector/transmitter terminal strip at the controller
12 • 35-3001A-01-02 Combustible Gas Sample-Draw DetectorStart UpThis section describes procedures to start up the sample-draw detector and place the
35-3001A-01-02 Combustible Gas Sample-Draw Detector • 136. If necessary, use a small flat-blade screwdriver to adjust the zero potentiometer until t
14 • 35-3001A-01-02 Combustible Gas Sample-Draw Detector4. Use the following formula to determine the correct test points output for the test sample.
35-3001A-01-02 Combustible Gas Sample-Draw Detector • 154. Calibrate the sample-draw detector as described in “Calibration” on page 18.5. If the fai
35-3001A-01-02 Combustible Gas Sample-Draw DetectorWARNINGRead and understand this instruction manual before operating detector. Improper use of the
16 • 35-3001A-01-02 Combustible Gas Sample-Draw Detector9. Turn on power to the controller and place it into normal operation.10. Turn on the control
35-3001A-01-02 Combustible Gas Sample-Draw Detector • 1710. Turn on power to the controller.11. Turn on the controller and place it into normal oper
18 • 35-3001A-01-02 Combustible Gas Sample-Draw DetectorCalibration FrequencyAlthough there is no particular calibration frequency that is correct fo
35-3001A-01-02 Combustible Gas Sample-Draw Detector • 19voltmeter reading is 100 mV (± 2 mV). If you used a zero air calibration cylinder to set the
20 • 35-3001A-01-02 Combustible Gas Sample-Draw DetectorParts ListTable 2 lists replacement parts and accessories for the combustible gas sample-draw
35-3001A-01-02 Combustible Gas Sample-Draw DetectorProduct WarrantyRKI Instruments, Inc. warrants gas alarm equipment sold by us to be free from def
35-3001A-01-02 Combustible Gas Sample-Draw DetectorTable of ContentsOverview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
35-3001A-01-02 Combustible Gas Sample-Draw Detector • 1OverviewThis operator’s manual describes the 35-3001A-01-02 combustible gas sample-draw detec
2 • 35-3001A-01-02 Combustible Gas Sample-Draw DetectorDescriptionThis section describes the components of the combustible gas sample-draw detector.
35-3001A-01-02 Combustible Gas Sample-Draw Detector • 3External ComponentsThis section describes the sample-draw detector’s external components.Hous
4 • 35-3001A-01-02 Combustible Gas Sample-Draw DetectorMain Circuit BoardThe main circuit board includes the detector/amp terminal strip, interconnec
35-3001A-01-02 Combustible Gas Sample-Draw Detector • 5counterclockwise to increase the flow and clockwise to decrease the flow.Status LEDsTwo statu