GX-2012 Operator’s Manual Using Maintenance Mode 117
during startup. From this screen, you can choose to continue accumulating
TWA and PEAK readings and the time in operation from the last time the
GX-2012 was used or start collecting new readings and reset the time in
operation.
1. Use the AIRS or (SHIFT)T buttons to display the LNCH BRK menu
item.
2. Press and release the POWER ENTER button. The screen will indicate
the current setting.
3. Use the AIRS or (SHIFT)T button to display the desired setting.
4. Press and release the POWER ENTER button to save the setting and
return to the main menu.
Updating the Alarm Latching Setting
With LATCHING set to ON (factory setting), the GX-2012 remains in alarm
condition until the alarm condition passes and the POWER ENTER button is
pressed.
With LATCHING set to OFF, the GX-2012 automatically resets an alarm
when the alarm condition passes.