Podsumowanie treści

Strona 1 - Operator’s Manual

RKI Instruments, Inc.www.rkiinstruments.com65-2405RK-03Combustible Gas TransmitterOperator’s ManualPart Number: 71-0333Revision: P1Released: 7/25/14

Strona 2

6 • 65-2405RK-03 Combustible Gas TransmitterWiring the Detector to the AmplifierWARNING: Always verify that the power to the controller is off before

Strona 3 - Product Warranty

65-2405RK-03 Combustible Gas Transmitter • 7 Figure 3: Wiring the Detector to the Amplifier10. Reinstall the detector terminal strip into its sock

Strona 4 - Table of Contents

8 • 65-2405RK-03 Combustible Gas TransmitterWiring the Amplifier to a Controller1. Turn off the controller.2. Turn off or unplug power to the control

Strona 5 - Specifications

65-2405RK-03 Combustible Gas Transmitter • 9Figure 4: Wiring the Amplifier to a Controller10. If shielded cable is used, connect the cable’s drain w

Strona 6 - Description

10 • 65-2405RK-03 Combustible Gas TransmitterStart UpThis section describes procedures to start up the combustible gas transmitter and place the tran

Strona 7 - Amplifier

65-2405RK-03 Combustible Gas Transmitter • 116. Turn the regulator’s on/off knob counterclockwise to open it. Gas will begin to flow.7. Allow the gas

Strona 8 - Installation

12 • 65-2405RK-03 Combustible Gas TransmitterPreparing for the response test1. Place the controller into its calibration mode or disable external ala

Strona 9 - 9.25 Max

65-2405RK-03 Combustible Gas Transmitter • 13TroubleshootingThe troubleshooting guide describes symptoms, probable causes, and recommended action for

Strona 10

14 • 65-2405RK-03 Combustible Gas Transmitter4. Remove the detector junction box’s cover from the junction box.5. Disconnect the detector leads from

Strona 11 - PWR / SIG

65-2405RK-03 Combustible Gas Transmitter • 15amplifier as shown in Figure 4 on page 9 of this manual. If controller leads or detector leads were remo

Strona 12

65-2405RK-03 Combustible Gas TransmitterWARNINGRead and understand this instruction manual before operating transmitter. Improper use of the transmit

Strona 13 - PWR / SIG

16 • 65-2405RK-03 Combustible Gas TransmitterCalibration FrequencyAlthough there is no particular calibration frequency that is correct for all appli

Strona 14 - Start Up

65-2405RK-03 Combustible Gas Transmitter • 17CalibrationThis section describes how to calibrate the combustible gas transmitter. It includes procedur

Strona 15 - Maintenance

18 • 65-2405RK-03 Combustible Gas Transmitter7. Leave the calibration adapter’s flexible tubing connected to the regulator.Setting the Response Readi

Strona 16 - Performing the response test

65-2405RK-03 Combustible Gas Transmitter • 19Parts ListTable 5 lists replacement parts and accessories for the combustible gas transmitter.Table 5:Pa

Strona 17 - Troubleshooting

65-2405RK-03 Combustible Gas TransmitterProduct WarrantyRKI Instruments, Inc. warrants gas alarm equipment sold by us to be free from defects in mate

Strona 18

65-2405RK-03 Combustible Gas TransmitterTable of ContentsOverview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Strona 19

65-2405RK-03 Combustible Gas Transmitter • 1OverviewThis manual describes the 65-2405RK-03 combustible gas transmitter. This manual also describes ho

Strona 20 - Determining Response Time

2 • 65-2405RK-03 Combustible Gas TransmitterDescriptionThis section describes the components of the combustible gas transmitter. The transmitter is a

Strona 21 - Calibration

65-2405RK-03 Combustible Gas Transmitter • 3sintered metal flame arrestor on one end allowing ambient air to diffuse into the detector. The flame arr

Strona 22 - Returning to Normal Operation

4 • 65-2405RK-03 Combustible Gas TransmitterTest PointsThe test points are on the left side of the amplifier (see Figure 1). The test points produce

Strona 23 - Parts List

65-2405RK-03 Combustible Gas Transmitter • 5Figure 2: Mounting the Combustible Gas Transmitter2. At the monitoring site you select, hang or mount th