www.rkiinstruments.com01 SeriesOperator’s ManualPart Number: 71-0093RKRevision: AReleased: 2/2/11
5 • Description 01 Series Operator’s ManualProtective Rubber BootsA protective rubber boot is installed over each end of the 01 Series. The sensor en
01Series Operator’s Manual Description • 6Alligator and Belt ClipsThe 01 Series is available with two types of clips, the alligator clip and the belt
7 • Description 01 Series Operator’s Manualnoticed, especially in the presence of H2S, change the charcoal filter disk (see the Maintenance section f
01Series Operator’s Manual Description • 8When either of the two control buttons are pressed, the LCD backlight comes on for 20 seconds.Control Butto
9 • Description 01 Series Operator’s ManualAlarm LightsThe 01 Series has two red LED alarm lights. They alert you to gas, low battery, and sensor fai
01Series Operator’s Manual Start Up • 10Start UpThis section explains how to start up the 01 Series and to get it ready for operation.Start-up Proced
11 • Operation 01 Series Operator’s ManualOperationThis section describes the normal operation of the 01 Series in Measuring Mode. It explains how th
01Series Operator’s Manual Operation • 121. The unit must be in Measuring Mode. The current gas concentration should be displayed on the LCD.2. Press
13 • Operation 01 Series Operator’s ManualAlarmsThis section covers alarm indications. It also tells you how to reset the 01 Series after an alarm ha
01Series Operator’s Manual Operation • 14Resetting Gas AlarmsTo reset a gas alarm, press the POWER/MODE button after the gas reading falls below the
01 Series Operator’s ManualWARNINGRead and understand this instruction manual before operating instrument. Improper use of the gas monitor could resu
15 • Operation 01 Series Operator’s ManualResponding to AlarmsThis section describes response to gas, over range, battery, sensor failure, and system
01Series Operator’s Manual Alarm Points • 16possible. Refer to the instructions in “Replacing the Batteries” for more information.Responding to a Sen
17 • Alarm Points 01 Series Operator’s Manual3. As soon as segments appear on the display (approximately one second), release the AIR button. When th
01Series Operator’s Manual Alarm Points • 18NOTE: If you press and hold the POWER/MODE button for too long (about five seconds), you will turn off th
19 • Calibration 01 Series Operator’s ManualCalibrationThis section covers the calibration of the 01 Series. Setting the fresh air reading is describ
01Series Operator’s Manual Calibration • 20NOTE: On the OX-01, instead of 100% nitrogen (0% oxygen), it is allowable to use higher than 0% oxygen to
21 • Calibration 01 Series Operator’s ManualNOTE: If one of the control buttons is not pressed within 10 minutes, the unit will return to Measuring M
01Series Operator’s Manual Maintenance • 22MaintenanceThis section describes troubleshooting procedures for the 01 Series. It also describes how to c
23 • Maintenance 01 Series Operator’s ManualReplacing the BatteriesWARNING: To prevent ignition of a hazardous atmosphere, batteries must only be cha
01Series Operator’s Manual Maintenance • 243. Rotate the captive battery cover screw counterclockwise to remove battery compartment door. 4. Carefull
01Series Operator’s Manual WarrantyWarrantyRKI Instruments, Inc. warrants the 01 Series Single Gas Monitor sold by us to be free from defects in mate
25 • Maintenance 01 Series Operator’s Manual4. Carefully remove the old sensor from the sensor socket. 5. Carefully insert the replacement sensor in
01Series Operator’s Manual Maintenance • 263. Rotate the membrane retainer about one-quarter turn counterclockwise to remove it from the sensor retai
27 • Parts List 01 Series Operator’s ManualParts ListTable 6lists replacement parts and accessories for the 01 Series.Table 6: Parts ListPart Number
01Series Operator’s Manual Parts List • 2881-1004RK Regulator, fixed flow, 0.5 LPM, for 58/34 liter aluminum cylinder, 103 liter steel cylinder81-110
Table of Contents 01 Series Operator’s ManualTable of ContentsIntroduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
01Series Operator’s Manual Table of ContentsMaintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1 • Introduction 01 Series Operator’s ManualIntroductionUsing an advanced microprocessor controlled detection system, the 01 Series Personal Single G
01Series Operator’s Manual Specifications • 2SpecificationsTable 1: 01 Series SpecificationsCO-01 HS-01/HS-01S OX-01Target Gas Carbon Monoxide (CO)Hy
3 • Specifications 01 Series Operator’s ManualOptional Accessories• Calibration Adapter• Calibration Kit• Alligator Clip• Belt ClipDimensions and Wei
01Series Operator’s Manual Description • 4DescriptionThis section describes the components of the 01 Series. These components include the 01 Series’