10/1/09 Price List (800) 754–5165
94
Fixed Systems Sensors & Transmitters
ESM-01 Sensor / Transmitter For Toxic Gases
Direct Connect Sensors
Non Explosion Proof Sensors, No J-box
65-2300RK-NH3 Sensor, Ammonia (NH3) sensor, 0 - 75 ppm, direct connection with conduit mounting,
non explosion proof (no transmitter, no j-box) ……………………………………………………………… 550.00
65-2300RK-ASH3 Sensor, Arsine (AsH3) sensor, 0 - 1.5 ppm, direct connection with conduit mounting,
non explosion proof (no transmitter, no j-box) ……………………………………………………………… 550.00
65-2300RK-HCN Sensor, Hydrogen Cyanide (HCN) sensor, 0 - 15 ppm, direct connection with conduit mounting
non explosion proof (no transmitter, no j-box) ……………………………………………………………… 550.00
65-2300RK-PH3 Sensor, Phosphine (PH3) sensor, 0 - 1 ppm, direct connection with conduit mounting,
non explosion proof (no transmitter, no j-box) ……………………………………………………………… 550.00
65-2300RK-SO2 Sensor, Sulfur Dioxide (SO2) sensor, 0 - 6 ppm, direct connection with conduit mounting,
non explosion proof (no transmitter, no j-box) ……………………………………………………………… 550.00
65-2301RK-NH3 Sensor, Ammonia (NH3) sensor, 0 - 75 ppm, direct connection,
non explosion proof with j-box (no transmitter) ………………………… 650.00
65-2301RK-ASH3 Sensor, Arsine (AsH3) sensor, 0 - 1.5 ppm, direct connection,
non explosion proof with j-box (no transmitter) ………………………… 650.00
65-2301RK-HCN Sensor, Hydrogen Cyanide (HCN) sensor, 0 - 15 ppm, direct connection,
non explosion proof with j-box (no transmitter) ………………………… 650.00
65-2301RK-PH3 Sensor, Phosphine (PH3) sensor, 0 - 1 ppm, direct connection,
non explosion proof with j-box (no transmitter) ………………………… 650.00
65-2301RK-SO2 Sensor, Sulfur Dioxide (SO2) sensor, 0 - 6 ppm, direct connection,
non explosion proof with j-box (no transmitter) ………………………… 650.00
Part# Description Suggested Retail
Part# Description Suggested Retail
Non Explosion Proof Sensors, With J-box
Note: Stainless steel junction box can be supplied for an additional $100.00 upon request instead of standard Aluminum junction box.