www.rkiinstruments.com Eagle 2 Maintenance Data LoaderOperator’s ManualPart Number: 71-0191RKRevision: DReleased: 5/29/14

Strona 2 - Warranty

7 • Launching the ProgramLaunching the Program 1. Click Start in the Windows® Icon Tray, then select Programs, then select Eagle 2 Maintenance Data L

Strona 3 - Table of Contents

Connecting an Eagle 2 to the Maintenance Data Loader Program • 8Connecting an Eagle 2 to the Maintenance Data Loader ProgramFollow these steps to con

Strona 4 - Introduction

9 • Connecting an Eagle 2 to the Maintenance Data Loader Program 3. Press and hold the POWER ENTER RESET button on the Eagle 2 until you hear a beep,

Strona 5 - System Requirements

Control Buttons • 10Control ButtonsThere are 5 control buttons on the main screen: Get Current EAGLE 2 Data, Select Distributed File, Transmit New Da

Strona 6

11 • Control Buttons 3. Click Get Current EAGLE 2 Data to retrieve the instrument’s user and station ID, catalytic combustible user defined gases, an

Strona 7 - IrDA Downloading Cable

Control Buttons • 12Transmit New DataAfter information has been updated in the parameter tabs, this button is used to upload that data to the Eagle 2

Strona 8 - Wireless Link Operation Note

13 • Station & User TabStation & User TabThe Station & User tab displays a list of Station IDs and User IDs. The first time the Eagle 2 i

Strona 9 - 6. Click OK

Station & User Tab • 14CSV FilesTo edit the Station ID or User ID list, you will need to import a csv (comma separated values) file into the prog

Strona 10 - Launching the Program

15 • Station & User TabThe csv files can be opened, edited, and saved using a word processing program such as Word, WordPad, or Notepad. The Stat

Strona 11 - Loader Program

Station & User Tab • 16 4. Open the saved files in Word, WordPad, or Notepad, enter new Station or User IDs, and save the files. 5. In the Statio

Strona 12

WarrantyWarrantyRKI Instruments, Inc. warrants gas alarm equipment sold by us to be free from defects in materials and workmanship, and performance f

Strona 13 - Control Buttons

17 • Conversion Table TabConversion Table TabThe Conversion Table tab is used to view the pre-defined relative response gases for the catalytic combu

Strona 14 - Select Distributed File

Conversion Table Tab • 18may contain any character in upper- or lower-case.•FactorThis value is the response factor for the listed gas relative to me

Strona 15 - Power OFF

19 • Conversion Table Tab• VoltThis value determines the sensor voltage for the catalytic combustible sensor. It can be set to 1.3 or 2.4. When set t

Strona 16 - Station & User Tab

Conversion Table Tab • 20blank. Any previously defined gases will appear. 3. Export the current data by pressing the “Export csv file” button. Choose

Strona 17 - CSV Files

21 • Conversion Table TabData Loader Program. The first value is the gas number, the second is the gas name, etc. 6. Edit the values you wish to chan

Strona 18 - Loading User and Station IDs

PID Sensor Tab • 22PID Sensor TabThe PID Sensor tab is used to view the pre-defined relative response gases and to view or define the 1 user-defined

Strona 19 - Station & User Tab • 16

23 • PID Sensor Tab• Full ScaleThis is the full scale value for the target gas.•PointThe point value indicates to what decimal place the gas readings

Strona 20 - Conversion Table Tab

PID Sensor Tab • 24There are limitations for the full scale and increment values that depend on the factor for both the high range and the low range.

Strona 21 - Conversion Table Tab • 18

25 • PID Sensor TabWhile the pre-defined gases may not be edited, the 1 user-defined gas may be edited by doing the following: 1. With Maintenance Da

Strona 22 - 19 • Conversion Table Tab

PID Sensor Tab • 26NOTE: Make sure you have downloaded the data from the EAGLE 2 to avoid erasing its data when updating the instrument using the Tra

Strona 23 - Conversion Table Tab • 20

Table of ContentsTable of ContentsIntroduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Strona 24 - 21 • Conversion Table Tab

27 • PID Sensor Tab 4. Open the csv file using Notepad, Word, or WordPad. The example below shows a csv file opened in WordPad. The user defined PID

Strona 25 - PID Sensor Tab

Obtaining a Relative Response Factor • 28correct, transmit the new data to the connected instrument by pressing “Transmit New Data”. Obtaining a Rela

Strona 26 - 23 • PID Sensor Tab

29 • Obtaining a Relative Response Factorcompound)• CAS No.-Sometimes it is easier to identify a VOC from the internationally recognized CAS (Chemica

Strona 27 - PID Sensor Tab • 24

Obtaining a Relative Response Factor • 30Gas/ VOC CAS No. Formula Relative Response Biphenyl 92-52-4 C12H10 0.4Bis(2,3-epoxypropyl) ether 7/5/38

Strona 28 - 25 • PID Sensor Tab

31 • Obtaining a Relative Response FactorGas/ VOC CAS No. Formula Relative Response Chloro-1,3-butadiene, 2- 126-99-8 C4H5Cl 3.2Chloro-1-fluoroe

Strona 29 - PID Sensor Tab • 26

Obtaining a Relative Response Factor • 32Gas/ VOC CAS No. Formula Relative Response Dichloro-1,1-difluoroethane, 1,2-1649-08-7 C2H2Cl2F2 ZR Dichlo

Strona 30 - 27 • PID Sensor Tab

33 • Obtaining a Relative Response FactorGas/ VOC CAS No. Formula Relative Response Dimethyl cyclohexane, 1,2- 583-57-3 C8H16 1.1Dimethyl disulp

Strona 31 - Response Factor

Obtaining a Relative Response Factor • 34Gas/ VOC CAS No. Formula Relative Response Ethyl hexanoate 123-66-0 C8H16O2 2.6Ethyl hexanol, 2- 105-7

Strona 32

35 • Obtaining a Relative Response FactorGas/ VOC CAS No. Formula Relative Response Hydroquinone 123-31-9 C6H6O2 0.8Hydroxypropyl acrylate 2- 999-

Strona 33

Obtaining a Relative Response Factor • 36Gas/ VOC CAS No. Formula Relative Response Methoxypropyl acetate 108-65-6 C6H12O3 1.2Methyl acetate 7

Strona 34

1 • IntroductionIntroductionCAUTION: Read and understand this manual before using the Eagle 2 Maintenance Data Loader Program. Also read and understa

Strona 35 - C2H2Cl2F2

37 • Obtaining a Relative Response FactorGas/ VOC CAS No. Formula Relative Response Nitropropane, 2- 79-46-9 C3H7NO2 ZR Nitrous oxide 10024-97-

Strona 36

Obtaining a Relative Response Factor • 38Gas/ VOC CAS No. Formula Relative Response Propylene oxide 75-56-9 C3H6O 7Propyleneimine 75-55-8 C3H7N

Strona 37 - C6H18OSi2

39 • Obtaining a Relative Response FactorGas/ VOC CAS No. Formula Relative Response Tributylamine 102-82-9 C12H27N 1Trichloro-1,1-difluoroethane,

Strona 38

Spare Parts List • 40Spare Parts ListTable 5: Spare Parts ListPart Number Description47-5027RK Cable, USB/IrDA adapter71-0154RK EAGLE 2 Operator’s Ma

Strona 39

System Requirements • 2next section.CAUTION: The Eagle 2 detects oxygen deficiency and elevated levels of oxygen, combustible gases, carbon monoxide,

Strona 40

3 • Installing the Eagle 2 Maintenance Data Loader ProgramInstalling the Eagle 2 Maintenance Data Loader Program 1. Launch Windows®. 2. Exit from all

Strona 41 - C12H27O4P

IrDA Downloading Cable • 4 5. Follow the on-screen instructions in the InstallShield Wizard Window to install the program. 6. If the InstallShield Wi

Strona 42

5 • IrDA Downloading CableInstalling an IrDA Adapter CableAfter installing the Eagle 2 Maintenance Data Loader Program, connect the IrDA/USB cable to

Strona 43 - Spare Parts List

IrDA Downloading Cable • 6 6. Click OK. 7. Close the Control Panel window. Figure 2: Image Transfer Tab